-
Smart Water
-
Smart Tank Farm
- DO Fluorescent Dissolved Oxygen Sensor
- ORP sensor
- pH sensor
- Ammonia nitrogen sensor
- Conductivity and pH two-in-one sensor
- Multiparameter sensor
- Self-cleaning turbidity sensor
- Inductive conductivity sensor
- Self-cleaning COD sensor
- Ultrasonic level meter
- Magnetostrictive level gauge
- Environmental water quality monitoring buoy
- Radar flowmeter
- Radar flowmeter
- Turbidity sensor
- Stainless steel rain gauge
- Radar water level gauge
- Residual chlorine sensor
- Electronic Water Scale (Type 485)
- Plate radar water level gauge
- Graphite conductivity sensor
- Bubble type water gauge
- Bubble gauge
- Salinity sensor
- Radar current meter
- Input level gauge
- Suspended solids (sludge concentration) sensor
- 24GHz radar water level gauge
-
Smart water conservancy
- Noise transmitter
- Beidou GNSS high precision receiver
- Pore water pressure gauge
- Air quality (PM2.5/PM10) transmitter
- Fluorescence dissolved oxygen transmitter
- Wind transmitter
- Industrial EC transmitters
- Wall mounted king shell temperature and humidity transmitter
- Industrial PH transmitter
- Wind speed transmitter
- On-line ammonia nitrogen sensor
- Electronic Water Scale (Type 485)
- On-line turbidity sensor
- Tip bucket rain gauge
-
Smart project products
CM510-71X
Product Features
Model No. | Network | Item | Interface | Dimension |
CM510-71F | 2G/3G/4G | DTU | RS232 | 100x62x24 mm |
CM510-71T | GSM/4G | DTU | RS232 | 100x62x24 mm |
CM510-71R | 2G/3G/4G/5G | DTU | RS232 | 100x62x24 mm |
Xiamen Caimore CM510-71X series DTU is an industrial-grade wireless data transmission equipment that supports different oversea networks. It supports GPRS/CDMA/WCDMA/TD-SCDMA/EDGE/FDD-LTE/TDD-LTE/5G.
The device provides TCP/UDP transparent wireless long-distance data transmission.
The device supports serial RS232 interface, the device can be directly connected to the above-mentioned interface devices of the customers, transparently transmit the data of the customer's PLC equipment and industrial control equipment to the customer's data center, and realize the functions of data collection, data transmission, and equipment control of the client equipment .
Adopt ARM7 industrial-grade processor and intelligent three-level protection, passed the 3000V electric shock test, possess patented technology, stable and reliable product performance.
This product has obtained the "Environmental Reliability Test Report" issued by MORLAB. The test items include: high temperature 80℃/humidity 85%, low temperature -30℃ and other tests. And, the high temperature and low temperature tests were used to continuously send and receive data for 4 hours in this environment.
This product has been widely used in power centralized meter reading, water meter centralized meter reading, heat network monitoring, gas monitoring, water conservancy monitoring, environmental protection testing, meteorological testing, earthquake monitoring, traffic control and other industries.
Technical Parameter
CM510-71X DTU | |
Serial Port | Data bits: 8 bits Stop bits: 1, 1.5, 2 Parity bit: no parity, odd parity, even parity Serial port rate: 300bps ~ 115200bps Flow control bit: no flow control 1*RS485 interface, 1*RS232 communication interface, 1*RS232 debugging interface |
Indicator Light | Online / ACT / Power |
Antenna Interface | Standard SMA female interface, 50 ohm; optional 3M/5M/10M/15M antenna extension cable, meet the different needs of customers |
SIM/UIM | 1.8V/3V/5V standard push-rod SIM card slot, built-in 15KV ESD protection |
Power Interface | Standard 3-pin locomotive power socket |
Powered By | |
Item | Description |
Recommended Power Supply | DC9V/1330mA |
Operating Voltage | Wide voltage design, DC5V to DC35V power supply can directly supply power to the device; and built-in power reverse protection and overvoltage and overcurrent protection |
Power Comsumption | |
Item | Description |
Average Communication Current | Average communication current :60mA@+12VDC |
Instantaneous Peak Current: | 25mA@+12VDC |
Standby Average Current | 25mA@+12VDC |
Physical Characterisitics | |
Item | Description |
Shell | Metal shell: anti-radiation, anti-interference; shell and system security isolation, lightning protection design; meet the power requirements of safety regulations; protection rating IP41; particularly suitable for harsh industrial control environments. |
Current | 100x62x24 mm(not including the antenna and the fixed parts) |
Weight | 0.41kg |
Other Parameters | |
Item | Description |
Operating Temperature | (-25 ºC ~+65ºC) |
Storage Temperature | (-40~+85ºC) |
Relative Humidity | 95%(No condensation) |
Product Size
Selection Guide
Model NO. | CM510-71F | CM510-71T | CM510-71R |
Standards and Frequency Bands | LTE-FDD:B1/B3/B8; | LTE-FDD: B1/B3/B5/B8 | 5G:n38/n40/n41/n77/n78/n79; |
he theory of bandwidth | LTE: max 10 Mbps (DL)/max 5 Mbps (UL) EDGE: max 236.8 kbps (DL)/max 236.8 kbps (UL) GPRS: max 85.6 kbps (DL)/max 85.6 kbps (UL)
| LTE: max 10 Mbps (DL)/max 5 Mbps (UL) EDGE: max 236.8 kbps (DL)/max 236.8 kbps (UL) GPRS: max 85.6 kbps (DL)/max 85.6 kbps (UL)
| 5G SA Sub-6:3.3Gbps (DL)/250Mbps (UL) |
Transmit Power | <24dBm | <24dBm | <24dBm |
Receiver Sensitivity | <-109dBm | <-109dBm | <-109dBm |
Application Scheme
1. Detection industry applications (pollution, meteorology, water pattern, water conservancy, earthquake, etc.)
2. Network management monitoring industry applications (gas pipe network, oil pipe network, heating network monitoring, water pipe network monitoring, etc.)
3. Oilfield monitoring, street light control, traffic control, vehicle guidance
4. Application cases in the power industry (power distribution monitoring, grid automation, automatic meter reading, grid dispatching)