Home > Product > Smart water conservancy > other >  Air quality (PM2.5/PM10) transmitter


LOADING IMAGES

Air quality (PM2.5/PM10) transmitter

PM2.5, PM10 output at the same timeUnique dual frequency data acquisition and
RS-PM-N01-2 is an industrial-grade general-purpose particle concentration transmitter. It adopts the principle of laser scattering measurement and conducts sieving through the unique dual-frequency data acquisition technology to obtain the equivalent particle size per unit volume of particles. The number of particles, and the particle mass concentration of equivalent particle size per unit volume is calculated by a unique scientific algorithm, and the data is output through the ModBus-RTU protocol through the 485 interface.
Sample Now

Product Features

RS-PM-N01-2 Is an industrial general particle concentration transmitter, the use of laser scattering measurement principle, through the unique dual-frequency data acquisition technology for screening, obtained the number of particles with equivalent particle size per unit volume, and scientific unique algorithm to calculate the particle mass concentration of equivalent particle size per unit volume, and to485Interface byModBus-RTUProtocol for data output. It can be used for outdoor weather station, dust monitoring, library, archives, industrial workshop and so onPM2.5orPM10Concentration monitoring site.


Functional features

◇ Range: 0-1000ug/m3, resolution: 1ug/m3

PM2.5 and PM10 output at the same time

Unique dual-frequency data acquisition and automatic calibration technology, consistency up to ±10%

Adopt advanced laser anti-attenuation technology to ensure long-term stability of equipment

Standard Modbus-RTU communication protocol, easy access


Technical Parameter

Dc power supply (default)

10~30V DC

Power consumption

0.5 W.

Transmitter circuit operating temperature and humidity

- 20℃~ + 60℃,0%RH~95%RH  The condensation

Communication interface

485Communication (modbus) protocol

Baud rate:2400,4800(Default),9600

Data bit length:8position

Parity check mode: None

Stop bit length:1position

The defaultModBusMailing Address:1

Supported function code:03

Parameter Settings

Use the provided configuration software to pass485Configuring interfaces

The resolution of the

1ug/m3

precision

Plus or minus10% (@ 500 ug/m3, 60% RH, 25℃)

Measuring range

PM2.5

0~1000ug/m3

PM10

0~1000ug/m3

Response speed

Or less90S

Warm up time

Or less2min

Product Size

Selection Guide

Application Scheme

Download Center