Smart Water
-
Smart Tank Farm
- DO Fluorescent Dissolved Oxygen Sensor
- ORP sensor
- pH sensor
- Ammonia nitrogen sensor
- Conductivity and pH two-in-one sensor
- Multiparameter sensor
- Self-cleaning turbidity sensor
- Inductive conductivity sensor
- Self-cleaning COD sensor
- Ultrasonic level meter
- Magnetostrictive level gauge
- Environmental water quality monitoring buoy
- Radar flowmeter
- Radar flowmeter
- Turbidity sensor
- Stainless steel rain gauge
- Radar water level gauge
- Residual chlorine sensor
- Electronic Water Scale (Type 485)
- Plate radar water level gauge
- Graphite conductivity sensor
- Bubble type water gauge
- Bubble gauge
- Salinity sensor
- Radar current meter
- Input level gauge
- Suspended solids (sludge concentration) sensor
- 24GHz radar water level gauge
-
Smart water conservancy
- Noise transmitter
- Beidou GNSS high precision receiver
- Pore water pressure gauge
- Air quality (PM2.5/PM10) transmitter
- Fluorescence dissolved oxygen transmitter
- Wind transmitter
- Industrial EC transmitters
- Wall mounted king shell temperature and humidity transmitter
- Industrial PH transmitter
- Wind speed transmitter
- On-line ammonia nitrogen sensor
- Electronic Water Scale (Type 485)
- On-line turbidity sensor
- Tip bucket rain gauge
-
Smart project products
Fluorescence dissolved oxygen transmitter
The calibration function provides a more simple and convenient calibration method.
It can be widely used in water treatment, aquaculture, environmental monitoring and other industries.
Product Features
• Dissolved oxygen measurement range 0~20mg/L (0~200% saturation).
• RS485 communication interface: MODBUS RTU communication protocol can be easily connected to the computer for monitoring and communication.
• You can set the ModBus communication address and change the baud rate.
• The equipment adopts wide voltage power supply, 10~30V DC.
• Using fluorescence measurement principle, no oxygen consumption, no electrolyte.
Technical Parameter
The power supply | DC 10~30V |
Power consumption | 0.2 W. |
Communication interface | RS485; The standardMODBUS-RTUAgreement; Baud rate: default4800(2400,4800,9600Can be set) |
Measuring principle | fluorescence |
Measuring range | 0~20mg/L(0 ~ 200%Saturation) |
Measurement error | Plus or minus3%FS; Plus or minus0.5℃ (25℃) |
The resolution of the | 0.01 mg/L;0.1%;0.1℃ |
The response time | Or less60sec |
Operating conditions of equipment | 0 ~ 40℃ |
Fluorescent film life | Normal use1years |
Storage conditions | - 10 to 60℃ |
Waterproof level | IP68 |
The electrode wire length | The default5m |
Shell material | Corrosion resistant plastic, stainless steel |